Installation manual for the Dynamiko Import air isola hy air inlet, with dimensions, aerodynamic data, acoustic insulation, water tightness, filter and…
This document is the installation manual for the Dynamiko Import air isola hy air inlet. It lists the unit dimensions, installation opening, exterior perforation, material, colors, nominal flow, humidity, section, water tightness, optional filter, and acoustic insulation values for specified combinations.
It also describes installation of the base, cap, optional round adjustment base, external wall cover, and CFA acoustic cover, plus cleaning and maintenance guidance and a warning about covering the inlets during outdoor air quality risks. This manual is written in Spanish.
| Aireador dimensions | 400 x 40 x 30 mm |
|---|---|
| Installation position | >1800 mm from finished floor |
| Exterior perforation section | 40 cm² freely distributed |
| Material | Polystyrene thermoplastic |
| Nominal flow at 20 Pa | 12.5 l/s and 1.6 l/s |
| Relative humidity | 60% and 45% |
| Section | 40 cm² |
| Water tightness without flow regulator | >150 Pa |
| Acoustic insulation, ISOLA HY + CE2A | Dn,e,w(C) 37 dB; Dn,e,w(Ctr) 37 dB |
| Acoustic insulation, ISOLA HY RA + CE2A | Dn,e,w(C) 39 dB; Dn,e,w(Ctr) 39 dB |
| Filter | Optional anti-dirt filter |
Use a vacuum cleaner for the interior parts; the outer grille can be cleaned with a damp cloth; the supplied anti-dirt filter can be washed with water and neutral soap; cleaning products should not be used.
Completely cover the air inlets with adhesive tape and disconnect mechanical extractors.
No, it is exclusively for surfaces sheltered from bad weather.
The base is held in place with three screws; the cap is push-fit and can also be screwed for more secure fastening.