User manual for the Dymax BlueWave QX4 high‑intensity LED point‑source curing system, covering safety, setup, operation and maintenance.
The Dymax BlueWave QX4 manual provides detailed instructions for safely installing, configuring, and maintaining the high‑intensity LED point‑source curing system. It is intended for experienced process engineers, technicians, and production staff who work with Dymax UV/visible light adhesives.
The guide describes system components, LED wavelength options (365 nm, 385 nm, 405 nm), intensity control from 10 % to 100 %, programmable modes, PLC integration, and recommended safety equipment such as UV‑protective eyewear and skin protection. Specifications, troubleshooting, and parts lists are also included. This manual is written in Chinese.
| LED intensity output | 13.9 W/cm² (RediCure), 18.8 W/cm² (PrimeCure), 14.9 W/cm² (VisiCure) |
|---|---|
| LED wavelengths | 365 nm, 385 nm, 405 nm |
| Power input | 100‑240 V ~ 2 A, 50/60 Hz |
| LED timer range | 0.1 – 999 seconds |
| Controller dimensions | 3.5" × 5.5" × 5.6" (9.0 cm × 14.1 cm × 13.7 cm) |
| Warranty period | 1 year from date of purchase |
| Operating environment | 5 °C – 40 °C (41 °F – 104 °F), no condensation |
The LED output can be set anywhere from 10 % to 100 % in 1 % increments using the front‑panel controls or PLC interface.
The system offers three LED wavelength options: 365 nm, 385 nm, and 405 nm.
The product is covered by a one‑year warranty from the date of purchase.