DSM Energy Control Solarcache Touch Energy Management System Installation Guide

Installation guide for the DSM Energy Control Solarcache Touch energy management system, covering wiring, mounting, commissioning, and parameter setup.


DSM Energy Control Solarcache Touch Energy Management System Installation Guide - cover page
Brand
DSM Energy Control
Category
Monitoring Equipment
Document type
Installation Guide
Language
English
Pages
8
File format
PDF
File size
370 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
53C2057F2DE75772B4247CEA87176D8A

About this manual

Solarcache Touch is a system from DSM Energy Control that diverts surplus generated energy to one or more heaters or resistive loads. It also monitors and records power and energy usage, showing current information and history over the past 28 days.

The installation guide covers inspecting existing wiring, choosing and mounting the power throttle and controller, making the electrical connections for Duo and Wi-Link versions, commissioning, and setting parameters. It is intended for a suitably qualified installer and notes that the separate User Guide should be given to the householder.

What's inside

  • General information
  • What’s in the box?
  • Inspect the wiring
  • Mount the power throttle
  • Mount the control unit
  • Wiring and connections
  • Commissioning

Specifications

Standard power throttle rating3 KW
Export power thresholdMore than 50 W
Export control targetBelow about 200 W
Historical data periodPast 28 days
CT lead extensionUp to 10 m
Recommended RCD30 mA

Frequently asked questions

What does Solarcache Touch do with surplus generated energy?

It diverts surplus generated energy to one or more heaters or resistive loads.

What export power level causes the immersion heater to be brought up?

When more than 50 W is being exported, Solarcache Touch brings up the immersion heater and adjusts the level to keep export below about 200 W.

Where should the controller be mounted?

It should be mounted at eye level where it can be read and operated easily, and the user should be consulted about the location.

How far can the CT clip leads be extended?

The CT clip leads can be extended up to 10 m using standard audio extension leads.