东方雨虹 PCC-501 Waterproof Coating Product Data Sheet

The PCC-501 cement‑based crystalline waterproof coating from 东方雨虹 offers deep penetration, strong anti‑leak performance and self‑repair for concrete structures.


东方雨虹 PCC-501 Waterproof Coating Product Data Sheet - cover page
Brand
东方雨虹
Category
Other
Document type
Product Leaflet
Language
Chinese
Pages
2
File format
PDF
File size
397 KB
Published
28 September, 2026
Updated
28 September, 2026
MD5 checksum
14CEF01E52F3FAD08A37A45DC9A72522

About this manual

PCC-501 is a powder‑type, cement‑based waterproof coating that penetrates concrete up to 5 cm, forms a rigid crystalline layer, and blocks pores and micro‑cracks to enhance durability. It meets GB 18445‑2012 standards and is suitable for basements, tunnels, water tanks, sewage pits, elevator shafts, pools and chemical plant structures.

The product is supplied in 20 kg plastic buckets. It is mixed with water at a 1:(0.35‑0.4) weight ratio and applied by brush or dry‑powder spray at temperatures between 5 °C and 35 °C. After brushing, the coating should be cured for at least 72 hours (ideally 7 days) before exposure to water. This manual is written in Chinese.

What's inside

  • Product Description
  • Packaging and Specifications
  • Performance Indicators
  • Applicable Scope
  • Product Features
  • Application Methods
  • Coating Curing
  • Transportation and Storage
  • Safety and Environmental Notes
  • Contact Information

Specifications

Physical statePowder
PackagingPlastic bucket, 20 kg
Fineness (0.63 mm sieve residue)≤ 5 %
Wet‑substrate bond strength (28 d)≥ 1.0 MPa
Permeability pressure ratio with coating (28 d)≥ 250 %

Frequently asked questions

What water‑to‑powder ratio should be used when mixing PCC‑501?

Mix powder and water at a weight ratio of 1 : (0.35‑0.4).

At what temperature range can PCC‑501 be applied?

The coating should be applied when the ambient temperature is between 5 °C and 35 °C.

How long must the coating be cured before it can be exposed to water?

Cure the coating for at least 72 hours; 7 days is ideal.

What is the maximum crack width that PCC‑501 can automatically repair?

The coating can self‑repair cracks up to 0.4 mm wide.