The Digilent Pmod MAXSONAR rev. A Reference Manual describes the ultrasonic range detector, its features, interfaces, and specifications.
The Pmod MAXSONAR rev. A is an ultrasonic range detector that uses the MaxBotix LV‑MaxSonar‑EZ1 sensor to provide 1‑inch resolution over a 6‑inch to 254‑inch range. It can deliver distance data via analog voltage, pulse‑width modulation, or a 5‑byte serial packet.
The module operates from 2.5 V to 5.5 V, draws about 2 mA typical current, and provides continuous measurements every 50 ms. Serial communication runs at 9600 baud, while analog and pulse‑width outputs scale the range to voltage and time respectively.
| Detection range | 6" – 255" |
|---|---|
| Sonar frequency | 42 kHz |
| Reading interval | Every 50 ms |
| Operating voltage | 2.5 V – 5.5 V |
| Typical current draw | 2 mA |
| Resolution | 1 inch |
| Minimum range | 6 inches |
| Maximum range | 254 inches |
| Analog scaling | (VCC/512) V per inch |
| Pulse‑width scaling | 147 µs per inch |
The module must be powered with a voltage between 2.5 V and 5.5 V.
Readings are available every 50 milliseconds.