Operating manual for the Di-LOG DL107 non-contact voltage detector, covering safety, specifications, and usage instructions for detecting AC voltage up to…
The Di-LOG DL107 is a non-contact voltage detector designed for the electrical industry, featuring a built-in flashlight and audible/optical alarm functions. It operates in two modes: a high voltage mode (90V - 1000V AC) for domestic supplies and three-phase systems, and a low voltage mode (24V - 1000V AC) for weak electromagnetic signals like audio systems and arc welding machines. The device ensures user safety with a CAT IV 1000V safety class rating and double insulation.
| Detection voltage range (Low) | 24V - 1000V AC |
|---|---|
| Detection voltage range (High) | 90V - 1000V AC |
| Frequency range | 50Hz/60Hz |
| Safety rating | CAT IV 1000V |
| Power supply | 2 x 1.5V AAA |
| Operating temperature | 0°C - 40°C |
| Dimensions | 150mm x 18mm x 23mm |
| Weight (net) | 50g |
The default setting is pre-programmed to high voltage mode, with a detection range of 90-1000V.
With an additional short press of the power button, the device switches to low voltage mode with a range of 24-1000V.
The detector will auto power off when it is not used for 5 minutes, or when the battery voltage is lower than 2.4V.
Di-LOG instruments are covered by a 24-month warranty for faults in manufacture and material defects.