DGH Corporation D5000 Series Users Manual

User manual for DGH Corporation D5000 Series modules covering installation, communications, commands, setup, power, troubleshooting, calibration, and…


DGH Corporation D5000 Series Users Manual - cover page
Brand
DGH Corporation
Category
Other Electronics
Document type
User Manual
Language
English
Pages
57
File format
PDF
File size
408 KB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
038593FD862F8B8CD31343B0A7457A04

About this manual

The DGH Corporation D5000 Series Users Manual covers getting started, functional description, communications, command set, setup, power supply, troubleshooting, calibration, and extended addressing for D5000 modules. It describes Default Mode, RS-232 and RS-485 connections, and configuration through the communications port.

The manual also includes command syntax, setup hints, error messages, an ASCII table, specifications, and factory values. It states that D5000 modules are not intrinsically safe devices and should not be used in an explosive environment unless enclosed in approved explosion-proof housings.

What's inside

  • Getting Started
  • Functional Description
  • Communications
  • Command Set
  • Setup Information and Command
  • Power Supply
  • Troubleshooting
  • Calibration
  • Extended Addressing
  • Appendix B D5000 Specifications

Specifications

Default Mode baud rate300 baud
Default Mode data bits8
Default Mode stop bits1
Default Mode parityNo parity
Default Mode address recognitionAny address
Factory channel address1
Factory baud rate300 baud
Factory linefeedsNo linefeeds
Factory parityNo parity
Factory alarmsOff
Factory echoNo echo
Factory delayTwo-character delay
RS-485 modules per cableUp to 30
RS-232C practical limitAbout 10 units
Intrinsic safetyNot intrinsically safe
Module channel addressesFour consecutive ASCII values

Frequently asked questions

How do I put a D5000 module into Default Mode?

Connect the DEFAULT* input pin to ground. This puts the module in a known communications setup without changing the values stored in EEPROM.

What communication settings are used in Default Mode?

Default Mode uses 300 baud, one start bit, eight data bits, one stop bit, no parity, and recognizes any address.

How many D5000 modules can be connected on one cable?

Up to 30 RS-485 modules may be strung together on one cable, while a practical limit for RS-232C units is about ten.

Are D5000 modules intrinsically safe?

No. D5000 modules are not intrinsically safe devices and should not be used in an explosive environment unless enclosed in approved explosion-proof housings.

Download PDF (408 KB)