Delta PG-03 B/V Series PG Speed Feedback Card Installation Guide

This installation guide covers wiring diagrams, encoder specifications, and connection precautions for the Delta PG-03 B/V series speed feedback card.


Delta PG-03 B/V Series PG Speed Feedback Card Installation Guide - cover page
Brand
PG-03
Category
Other Electronics
Document type
Installation Guide
Language
Chinese
Pages
4
File format
PDF
File size
259 KB
Published
16 January, 2012
Updated
18 October, 2026
MD5 checksum
CB76E3BB71FF295037ACBD772813CB4B

About this manual

The document serves as an installation manual for the Delta PG-03 B/V series PG speed feedback card. It provides essential information including a wiring diagram connecting to a VFD-V motor drive and details on compatible encoder specifications.

Key sections include precautions for cabling to prevent interference, specific wire gauge recommendations (AWG24~AWG18), and a table detailing maximum cable lengths based on the encoder output type (Voltage, Open Collector, Line Driver, or Complementary). This manual is written in Chinese.

What's inside

  • Wiring Diagram
  • Encoder Specifications
  • Cabling Precautions
  • Wire Gauge Recommendations
  • Maximum Cable Lengths
  • Terminal Definitions
  • FSW2 Switch Settings

Specifications

Encoder Power Output Voltage+12V±5%
Recommended Wire GaugeAWG24~AWG18
Max Length for Voltage Output Type50m
Max Length for Open Collector Type50m
Max Length for Line Driver Type300m
Max Length for Complementary Type70m

Frequently asked questions

What is the recommended wire gauge for this card?

The appropriate wire specification is between AWG24 and AWG18.

What is the maximum acceptable pulse rate for the encoder?

The card can accept a maximum of 500KP/Sec.

What wire gauge range is appropriate for the connections?

The recommended wire size ranges from AWG24 to AWG18.

How long can the wiring be for a voltage output type encoder?

For voltage output types, the maximum length is 50m.