Dell PowerConnect W-6000 Fan Tray (HW-FT) Installation Guide

Installation guide for the Dell PowerConnect W-6000 fan tray (HW-FT), covering features, LED status indicators, and hot-swap replacement steps.


Dell PowerConnect W-6000 Fan Tray (HW-FT) Installation Guide - cover page
Brand
DELL
Category
Network Switches
Document type
Installation Guide
Language
Chinese
Pages
6
File format
PDF
File size
433 KB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
18EFDAF9712144AECBB4DB6AD5D29674

About this manual

This document is the installation guide for the fan tray (HW-FT) of the Dell PowerConnect W-6000 controller chassis. The fan tray provides cooling for the W-6000M3 module and is required for normal operation; the W-6000 chassis operating temperature range is 0 to 40 °C (32 to 104 °F), and the software raises warnings when temperature thresholds are exceeded. The guide describes the tray's general and physical features, including built-in redundancy (three independent fans), hot-swapping, the tray slot location, and the status LED indications.

It then gives step-by-step instructions for replacing the fan tray: preparing the new tray, loosening the captive screws, separating and removing the old tray, inserting and seating the new one, and securing it. Because the W-6000 has no shutdown function, a hot-swap replacement must be completed within one minute; if two or more fans fail (amber/red LED), the chassis must be shut down and cooled before restart. The document closes with safety and regulatory notices (FCC Part 15, Canadian ICES-003), Dell support links, and copyright/legal statements noting the product is sourced from Aruba Networks. This manual is written in Chinese.

What's inside

  • 特性 (Features)
  • 外形描述 (Physical description)
  • 风扇状态 LED (Fan status LED)
  • 更换风扇架 (Replacing the fan tray)
  • 准备新风扇架 (Preparing the new fan tray)
  • 拆卸旧风扇架 (Removing the old fan tray)
  • 装入新风扇架 (Installing the new fan tray)
  • 安全性及合规性 (Safety and compliance)
  • 支持与联系 (Support and contact)
  • 法律声明 (Legal notices)

Specifications

Chassis operating temperature0 to 40 °C (32 to 104 °F)
Minor temperature alarm40 °C
Major temperature alarm50 °C
Critical temperature alarm60 °C
Fans per tray3 independent fans
Hot-swap time limit1 minute
Fan tray slot locationLeft side of the W-6000 chassis, extending from front to back

Frequently asked questions

What does the fan tray status LED mean when it is amber?

An amber LED means one fan has failed, but the remaining two fans can still provide adequate cooling until the fan tray is replaced.

What should I do if two or more fans in the tray fail?

Shut down the W-6000, replace the fan tray, let the chassis cool for at least five minutes, then power it back on.

Where can I download the latest Dell PowerConnect W-6000 documentation?

The latest user, reference, and installation guides are available at support.dell.com/manuals.

Download PDF (433 KB)

More DELL Manuals


View all DELL manuals →