Installation manual for the Daikin EKRTR room thermostat and optional EKRTETS external temperature sensor, covering mounting, code setup and technical…
The Daikin EKRTR room thermostat controls Daikin systems for radiator heating and floor heating/cooling applications. It can be wall-mounted or used as a table-top model, and the optional EKRTETS sensor can be connected as an external ambient or floor temperature sensor.
The manual covers installation of the thermostat and receiver, code setup in the installer menu, and technical characteristics for the thermostat, receiver and optional sensor.
| Temperature readout | Steps of 0.1°C/0.1°F |
|---|---|
| Operating temperature (thermostat) | 0°C~50°C/32°F~122°F |
| Setpoint temperature range | 4°C~37°C in steps of 0.5°C; 39.5°F~99°F in steps of 0.5°F |
| Electrical protection (thermostat) | Class II - IP30 (indoor use, polution degree 2) |
| Feeding and autonomy | 3 alkaline batteries AA.LR6 1.5 V, approximately 2 years |
| Electrical protection (receiver) | Class II - IP44 (indoor use, polution degree 2) |
| Power supply (receiver) | 1N~50 Hz 230 VAC |
| Radio frequency | 433.92 MHz, <10 mW |
| Range | approximately 100 m in open space; approximately 30 m in residential environment |
| Output relays maximum load | 4 A - 230 VAC |
| Maximum fuse amp | 3 A |
| Power consumption | 15 W, maximum |
| Immunity against voltage surges | Category III (2.5 kV) |
| Type of automatic action | 1C |
| External temperature sensor | NTC 10K at 25°C/3 meter lead; NTC 10K at 77°F/3 meter lead |
It can be used to control the Daikin system for radiator heating and floor heating/cooling applications.
Only if the optional EKRTETS temperature sensor is not installed as an external temperature sensor.
It can be used as an external ambient temperature sensor or as a floor temperature sensor for floor heating/cooling applications.
It uses 3 alkaline batteries AA.LR6 1.5 V, with autonomy of approximately 2 years depending on usage conditions.