Operating instructions for Crypto AG 580 Series Base/Repeater devices including control buttons, display elements, and communication modes.
This manual covers the operation of Crypto AG 580 Series Base/Repeater units (REP-580, REF-580, BRF-580, BSC-580). It assumes correct programming, installation, and loading of secure key sets. Without communication keys, the device functions only as a repeater. The manual details control unit buttons, display symbols, volume control, channel selection, and transmission modes including plain, default, and ciphered operations.
Key features include PTT switch placement based on handset or microphone use, emergency clear function, and output power settings. Error messages and troubleshooting are also described for operational issues.
| Model | 580 Series Base/Repeater (REP-580, REF-580, BRF-580, BSC-580) |
|---|---|
| Communication Modes | Plain, Ciphered, Default Key |
| Output Power | 5 Watt, 15 Watt (portable high/fixed low) |
The device will work only as a repeater and base station function is not possible.
Press STO 1 for plain, STO 2 for ciphered, and STO 3 for default key operation.
Press shift key, then EXP (C), then within 5 seconds press numerical key 9 and CL (6).