Broseley York Midi Gas Stove Installation and Operation Manual

Installation and operation manual for the Broseley York Midi gas stove, covering assembly, flue and gas connections, coal layout, and servicing.


Broseley York Midi Gas Stove Installation and Operation Manual - cover page
Brand
Broseley
Category
Gas stove
Document type
User Manual
Language
English
Pages
19
File format
PDF
File size
296 KB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
150015A8048ED72B523964EB0E69C5E2

About this manual

The Broseley York Midi is a gas-fired radiant convector stove designed to run on either natural gas or LPG, with non-interchangeable burner units for the two gas types. The manual provides technical information, dimensions, siting requirements, assembly steps, flue and gas connection guidance, pressure testing, coal layout, operating instructions, and servicing information.

It states that installation must comply with national regulations and be carried out by a qualified and accredited gas fitter on the Gas Safe register. It also covers ventilation, spillage testing, troubleshooting, and the guarantee, and lists specifications including heat input, supply pressure, dimensions, and weight.

What's inside

  • Technical Information
  • Dimensions & Details
  • Siting the Appliance
  • Stove Assembly
  • Flue Connection
  • Ventilation
  • Gas Connection
  • Pressure Testing
  • Arranging the Layout of the Coals
  • Operating the Stove

Specifications

Heat input (gross), natural gas6.2 Kw/Hr
Gas rate, natural gas0.59 M3/Hr
Width457 mm (18 in)
Weight excluding optional canopy65 kg (143 lbs)
Maximum heat output (approx.)4.6 kilowatts
Flue spigot diameter127 mm (5 in)
Minimum hearth thickness12 mm
Gas supply connection pipe8 mm semi-rigid, max 1 m

Frequently asked questions

What gas types can the York Midi gas stove use?

The York Midi is designed to run on either natural gas or LPG. The burner units are not interchangeable between the two gas types.

Who is allowed to install the York Midi gas stove?

Installation, assembly and commissioning must be carried out by a professionally qualified and accredited gas fitter listed on the Gas Safe register. The manual says not to install the appliance yourself.

What gas pressure is required for natural gas?

For natural gas, the pressure is 20 mbar measured at the burner test nipple with the appliance at full rate.

What is the minimum flue height?

The flue must have a minimum height of 3 metres to ensure adequate draught.