BISCO eCEMENT Adhesive Cementation System Instructions for Use

Instructions for using the BISCO eCEMENT Adhesive Cementation System for cementing Lithium Disilicate ceramic restorations, including preparation and…


BISCO eCEMENT Adhesive Cementation System Instructions for Use - cover page
Brand
Bisco
Category
Other
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
289 KB
Published
28 October, 2026
Updated
28 October, 2026
MD5 checksum
10A7A09B80DF34CE98763AE416849989

About this manual

This document provides instructions for the BISCO eCEMENT Adhesive Cementation System, designed for the cementation of Lithium Disilicate ceramic restorations such as IPS e.max. The system includes both light-cure and dual-cure resin cements to ensure exceptional retention and esthetics for various restoration types.

The manual details the indications for use, contraindications, and safety warnings regarding the components. It provides step-by-step instructions for restoration preparation, tooth preparation using either self-etching or total-etching techniques, and the final cementation process for both thin and thick restorations.

What's inside

  • General Information
  • Indications for Use
  • Contraindications
  • Warnings
  • Cautions
  • Precautions
  • Restoration Preparation and Try-In
  • Tooth Preparation
  • Cementation
  • Technical Information

Specifications

Working Time (Dual-Cure)Minimum 2 minutes at 22°C (71.6°F)
Setting Time (Dual-Cure)Maximum 3 minutes, 30 seconds at 37°C (98.6°F)
Etch Time (Lithium Disilicate)25 seconds
Primer Dwell Time30 seconds
Adhesive Coat Application Time10-15 seconds per coat
Adhesive Air-Dry TimeAt least 10 seconds
Adhesive Light Cure Time10 seconds
Cement Light Cure Time (Tack)3-5 seconds
Cement Final Light Cure TimeUp to 40 seconds from lingual and 40 seconds from the facial

Frequently asked questions

What types of restorations is the eCEMENT system indicated for?

It is indicated for Lithium Disilicate ceramic restorations such as IPS e.max, including veneers, crowns, inlays, onlays, and three-unit bridges.

Can the eCEMENT system be used with high-strength zirconia or alumina restorations?

No, the system excludes high-strength zirconia/alumina restorations.

What safety precautions are required when using the etchants?

Protective eyewear and gloves must be worn. A rubber dam is recommended. Hydrofluoric acid is a severe eye and tissue irritant.

Download PDF (289 KB)