Installation and user manual for the BFT CellCOM+ cellular gate intercom, covering installation, wiring, SMS programming, keypad use, and app setup.
This is the installation and user manual for the BFT CellCOM+ Cellular Intercom System, product version 2.3.2, published by BFT (BFTGateOpeners.com). The manual states the system should be installed by a professional automatic gate installer or access control specialist, and recommends setting up, configuring and testing the system on a workshop bench before taking it to site.
The contents cover a site survey for GSM coverage, SIM card preparation, power wiring, call box mounting, connections on the GSM controller and to the gate controller, programming the GSM unit by SMS text messages, keypad programming and use, intercom operation, control by SMS, optional app setup on iPhone and Android, plus maintenance and troubleshooting. The unit operates on AT&T and T-Mobile networks in the USA.
| Power supply | 15V DC 3A |
|---|---|
| Power cable | 14 gauge, 25 feet max |
| Call box fuse | 400mA quick blow |
| Network system | Dual 2G/3G |
| Frequency bands | 850/900/1800/1900 MHz |
| Carriers (USA) | AT&T and T-Mobile |
| Dial-out numbers | Up to 3 telephone numbers in sequence |
| Caller ID memory | Up to 100 numbers |
A regular voice and SMS SIM card from AT&T or T-Mobile. Data-only SIM cards will not work in the unit.
Programming is done by sending SMS text messages to the unit from a phone, starting with the pass code followed by commands separated by #.
It dials up to 3 telephone numbers in sequence, and the ringing time for each number can be set by SMS.
The unit reports a signal level from 1 to 31; 21-31 is good, and levels below 12 can cause relay and audio problems.