BERNARD SQX & STX INTELLI+ Series Electric Actuator User Manual

This manual provides operating instructions for BERNARD SQX & STX INTELLI+ series electric actuators, covering safety, installation, wiring, remote control…


BERNARD SQX & STX INTELLI+ Series Electric Actuator User Manual - cover page
Brand
Bernard
Category
Industrial Robot
Document type
User Manual
Language
Chinese
Pages
23
File format
PDF
File size
3.1 MB
Published
22 October, 2026
Updated
22 October, 2026
MD5 checksum
EA5AA894EBA5B4D21B58B536BC7D2072

About this manual

This manual covers the SQX & STX INTELLI+ series of electric actuators manufactured by BERNARD CONTROLS. It provides comprehensive instructions for safe operation, installation, and maintenance, specifically designed for use in hazardous explosive environments. The document details compliance with ATEX, IECEx, and INMETRO standards, ensuring suitability for gas and dust zones. This manual is written in Chinese.

What's inside

  • Safety Instructions
  • Product Overview
  • Storage
  • Valve Connection
  • Electrical Wiring
  • Remote Control
  • Local Control
  • Menu Navigation
  • Settings and Modification
  • Troubleshooting

Specifications

Explosion Protection TypeEx d, Ex de, Ex tb
Temperature ClassT135°C
Operating Temperature Range-20°C to +70°C
Maximum Supply Voltage690V
Maximum Control Voltage160V
Maximum Power Cable Section6mm2
Maximum Control Cable Section4 mm2

Frequently asked questions

What batteries are required for the battery-equipped actuators?

The manual specifies using 2 OMNICEL ER14505HD, 2 MICROBAT ER 14505 M, or 2 EVE ER 14505M batteries.

Can the Intelli+ infrared communication component be used in explosive areas?

No, the Intelli+ infrared communication component is not explosion-proof and should not be used in explosive zones.

How often should the bearings be replaced?

The bearings should be replaced every 10,000 hours of operation.