Beck 990 Display Differential Pressure Transmitter Data Sheet

Data sheet for the Beck 990 Display differential pressure transmitter with technical data, pressure ranges, order matrix, accessories and connection diagram.


Beck 990 Display Differential Pressure Transmitter Data Sheet - cover page
Brand
Beck
Category
pressure transmitters
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
543 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
1C5168F75B721A585DFAC847192389AC

About this manual

The Beck 990 Display series differential pressure transmitter measures differential pressure, overpressure and vacuum in gaseous, non-combustible and non-aggressive media. It offers one adjustable pressure range (from 100% down to 50% of full scale via the menu), switchable display units (kPa, mbar or inWC), a switchable output signal of 0...10 V or 4...20 mA, an adjustable response time from 0.1 to 20 s, and two adjustable potential-free switching outputs (S1 up to 50 VAC/5 A, S2 up to 250 VAC/5 A).

Typical applications include building automation and air conditioning systems, overpressure measurement in clean rooms and laboratories, constant pressure measurement in VAV applications, and dynamic filter and ventilator monitoring. The document lists technical data, available pressure ranges from 0...25 Pa to 0...250 kPa, an order matrix for the 990M (manual offset calibration) and 990A (automatic zero offset compensation) variants, accessories such as Climaset hose kits, and a connection diagram with dimensional drawings.

What's inside

  • General description
  • Applications
  • Adjustable pressure range
  • Switchable pressure units
  • Switchable output signal
  • Switching output
  • Technical data
  • Pressure ranges
  • Order matrix
  • Accessories

Specifications

Supply voltage18 ... 30 VAC / VDC
Output signal0 ... 10 V or 4 ... 20 mA
MediumAir and non-combustible and non-aggressive gases
Linearity≤ ±0.5% FS, min. ±1 Pa
Uncertainty±1% FS, min. ±1 Pa
Humidity0 ... 95% rel, non-condensing
Measuring methodPiezoresistive pressure transducer
Process connection4 mm and 6 mm hose connection
DisplayRed 7 segment LED display, 4 digits
Housing dimensions143 x 96 x 48 mm
Weightapprox. 230 g
Switching output S1max. 50 VAC/5 A
Switching output S2max. 250 VAC/5 A

Frequently asked questions

Which output signals does the 990 Display support?

The output signal can be switched in the menu between 0...10 V and 4...20 mA.

Which pressure units can be shown on the display?

Three units can be selected in the menu: Pascal (kPa, factory setting), mbar or inWC.

How is the zero offset calibrated on the 990 series?

The 990M can be re-calibrated to zero in the menu in a pressureless state, while the 990A performs an automated zero offset compensation.

Can the transmitter be used for volume flow measurement?

Yes, the output signal shape can be changed in the menu from linear to square rooted to enable volume flow measurement via a differential pressure reading.