This manual provides operating, installation, and maintenance instructions for BD SENSORS DS 230 electronic pressure switches and DM 230 digital pressure…
This user manual covers the operation, installation, electrical connection, initial use, and maintenance of the BD SENSORS DS 230 electronic pressure switch and DM 230 electronic digital pressure gauge. It is intended for professional technicians and includes safety warnings, installation steps for DIN 3852 and NPT interfaces, and electrical wiring diagrams. This manual is written in Chinese.
| Interface Standard (DS 230) | DIN 3852 |
|---|---|
| Interface Standard (DM 230) | NPT |
| Torque (DIN 3852) | 5 Nm |
| Torque (NPT) | 30 Nm |
| Electrical Interface | M12x1 (5-pin) |
| Display | 4-digit LED |
This manual is intended for professional technicians.
Installation must be performed with no pressure and no power supply.
Screw the device in by hand and then tighten it with a wrench to approximately 5 Nm.