Service manual for the BAL Accu-Slide System covering troubleshooting, cable adjustment, cable replacement, and replacement kits.
This service manual for the BAL Accu-Slide System provides troubleshooting and service procedures for the slide room mechanism. It lists common problems and solutions, the tools needed, cable adjustment steps, and procedures for cable replacement, wipe installation, jamb clamp replacement, and manually moving the room.
A serviceable items section lists replacement kits, including Repair Kit 22305, Repair Kit 22307, Cable Repair Kit, Repair Kit 22309, Repair Kit 22311, and Motor Repair Kit.
| Room travel for adjustment procedure | More than 24 inches |
|---|---|
| Cable slack when room is seated full out | Approximately 1/2 inch up or down (1 inch total movement) by hand |
| Jam nut size | 1/4-20 |
| Manual drive fitting | 1/4-inch hex on motor end |
The manual lists detached cables, a chain caught on a bracket, a chain off the sprocket, and a broken shaft key as causes; it advises checking cable tension and opening the access panel to re-adjust.
Attach the included flexible shaft to the 1/4-inch hex fitting on the motor, then use a 1/4-inch socket and ratchet or a drill to turn it in the proper direction.
The listed tools include a power driver, 3/8- and 7/16-inch sockets, two 3/8-inch wrenches, two 7/16-inch wrenches, Vice Grips, a flex-shaft, cable cutters, and a crimping tool.
The replacement kits listed are Repair Kit 22305, Repair Kit 22307, Cable Repair Kit, Repair Kit 22309, Repair Kit 22311, and Motor Repair Kit.