AVG Autotech Touch•PLS Programmable Limit Switch Instruction & Operation Manual

Instruction and operation manual for the AVG Autotech Touch•PLS programmable limit switch with graphical touchscreen operator interface.


AVG Autotech Touch•PLS Programmable Limit Switch Instruction & Operation Manual - cover page
Brand
AVG Autotech
Category
Automation control Equipment
Document type
User Manual
Language
English
Pages
90
File format
PDF
File size
1.4 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
57601841F0BBE09D0A400A39C5BB5381

About this manual

This manual covers the Touch•PLS, a programmable limit switch (PLS) with a graphical touchscreen operator interface from AVG Autotech, the company that introduced the first microprocessor-based PLS in 1975. The unit uses a resolver as its position transducer and can run stand-alone with a factory-installed Core Program, or be integrated with a PLC using the included uWIN programming software.

The document explains installation (mounting templates for 5-inch color, 5-inch TFD color, 6-inch monochrome and 10-inch color models, DIP switch settings and resolver wiring), PLS functions such as speed compensation, ModZ and brake wear monitoring, the Core Program screens, how to modify the Core Program with uWIN, ordering information, troubleshooting, and maintenance procedures including lithium battery, fuse and backlight bulb replacement.

What's inside

  • Overview
  • Specifications
  • Touch•PLS Installation
  • PLS Functions
  • Touch•PLS Core Program
  • Modification of Core Program
  • How to Order
  • Troubleshooting
  • Replacement Parts & Maintenance

Frequently asked questions

Can the Touch•PLS perform both ModZ and Brake Wear Monitoring at the same time?

No. The PLS can be field programmed to have either ModZ or Brake Wear Monitoring functionality, but it cannot perform both at the same time.

How many password levels does the Touch•PLS support?

The Touch•PLS has a Password Protection feature eight levels deep, with up to eight user-programmable passwords that allow access to different screens.

What software is used to modify the Touch•PLS Core Program?

The uWIN Programming Software (P/N 10F64), included with the unit, is installed on a PC and used to modify the Core Program.

What position transducer does the Touch•PLS use?

The Touch•PLS uses a resolver as a position transducer, such as AVG Autotech's RL100, E7R and E8R Series resolvers, which gives true machine position even after a power outage.