Instruction and operation manual for the AVG Autotech Touch•PLS programmable limit switch with graphical touchscreen operator interface.
This manual covers the Touch•PLS, a programmable limit switch (PLS) with a graphical touchscreen operator interface from AVG Autotech, the company that introduced the first microprocessor-based PLS in 1975. The unit uses a resolver as its position transducer and can run stand-alone with a factory-installed Core Program, or be integrated with a PLC using the included uWIN programming software.
The document explains installation (mounting templates for 5-inch color, 5-inch TFD color, 6-inch monochrome and 10-inch color models, DIP switch settings and resolver wiring), PLS functions such as speed compensation, ModZ and brake wear monitoring, the Core Program screens, how to modify the Core Program with uWIN, ordering information, troubleshooting, and maintenance procedures including lithium battery, fuse and backlight bulb replacement.
No. The PLS can be field programmed to have either ModZ or Brake Wear Monitoring functionality, but it cannot perform both at the same time.
The Touch•PLS has a Password Protection feature eight levels deep, with up to eight user-programmable passwords that allow access to different screens.
The uWIN Programming Software (P/N 10F64), included with the unit, is installed on a PC and used to modify the Core Program.
The Touch•PLS uses a resolver as a position transducer, such as AVG Autotech's RL100, E7R and E8R Series resolvers, which gives true machine position even after a power outage.