Avdel 74200 Threaded Insert Power Tool Instruction Manual

This manual provides operating, maintenance, and safety instructions for the Avdel 74200 hydro-pneumatic threaded insert power tool.


Avdel 74200 Threaded Insert Power Tool Instruction Manual - cover page
Brand
Avdel
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
526 KB
Published
10 October, 2026
Updated
10 October, 2026
MD5 checksum
8E70B361DF3AB4A815CC8F11528C2EDD

About this manual

The document serves as an instruction manual for the Avdel 74200 Threaded Insert Power Tool. It covers essential topics including safety rules, tool specifications, intended use, dimensions, and detailed procedures for putting the tool into service, adjusting strokes, and operating it correctly.

Additionally, the guide provides comprehensive instructions for fitting and servicing nose assemblies, performing daily and weekly maintenance tasks such as checking the pneumatic cylinder and rod guide, and troubleshooting common faults. It also includes information on the limited warranty and safety data regarding priming oil.

What's inside

  • Safety Rules
  • Tool Specifications
  • Intent of Use
  • Tool Dimensions
  • Putting into Service
  • Stroke Adjustment
  • Nose Assemblies Fitting & Servicing Instructions
  • Servicing the Tool Daily / Weekly
  • Maintenance Pneumatic Cylinder
  • Fault Diagnosis

Specifications

Air Pressure (Minimum - Maximum)5-7 bar (75-100 lbf/in2)
Free Air Volume Required @ 5 bar/75 lbf/in28 litres (.28 ft3)
Stroke (Maximum)7 mm (.276 in)
Motor Speed (Spin On / Spin Off)2000 rpm
Pull Force @ 5 bar/75 lbf/in219.1 kN (4300 lbf)
Cycle timeApproximately 2.5 seconds
Noise LevelLess than 75 dB(A)
Weight (Without nose equipment)2.2 kg (4.85 lb)

Frequently asked questions

What is the optimum operating pressure for the tool?

All tools are operated with compressed air at an optimum pressure of 5.5 bar.

What safety glasses requirement is mentioned for the operator?

The wearing of safety glasses is required both by the operator and others in the vicinity to protect against pin ejection.

How often should nose assemblies be serviced?

Nose assemblies should be serviced at weekly intervals.