User guide for the Audio Research Reference 10 stereo preamplifier covering installation, connections, operation, touch screen use, maintenance, warranty…
The Reference 10 is a stereo preamplifier from Audio Research supplied as an audio chassis and a power supply chassis. The guide covers installing the vacuum tubes, placing the unit in a system, making analog and RS-232 connections, and the power-up and shut-down procedures.
It also describes front-panel and remote-only controls, interactive touch screen operation, troubleshooting, servicing, cleaning, disposal and recycling, the limited warranty, and specifications. Audio Research notes that the vacuum tubes normally need replacement after about 4,000 hours of use.
| Input connectors | Seven pairs of BAL/SE inputs: 1, 2, 3, 4, 5, 6, and Processor |
|---|---|
| Main outputs | Two pairs of BAL/SE main outputs |
| Power requirements | 235W max, 50/60 Hz |
| Fuse | SLO-BLO T4A (230V) |
| Remote start jacks | +12V DC input/output jacks |
| Tube replacement interval | Approximately 4,000 hours of use under normal use |
The umbilical cables between the two chassis must be connected first. Powering up without them can cause significant, non-warranted damage.
With normal use, Audio Research says they should not need to be changed for approximately 4,000 hours.
No. For each input, use either the BAL or SE connector, never both at the same time.
Audio Research provides a 3-year limited warranty, with a 90-day limited warranty for vacuum tubes.