User manual for the AU3TECH FTC 91 Series laser focus tracking controller: panel ports, parameters, installation, debugging and maintenance.
This user manual describes the AU3TECH FTC 91 Series, a fiber focus tracking controller that uses capacitive sensing to track and adjust the distance between the laser cutting head and the processing parts in real time, so the cutting point stays at the best position of the laser focus. The document is intended for installation engineers, maintenance engineers and operators.
The manual covers the product panel and ports, the interface hierarchy and parameters (calibration, mechanical, operating, technological, alarm and system), function descriptions such as tracking control and alarm protection, installation and connection, debugging steps including servo and floating head calibration, accessories, operation and maintenance, and a technical index.
| Operating temperature (FTC) | -10 °C to +55 °C |
|---|---|
| Operating temperature (capacitance sensory package) | -10 °C to +300 °C |
| Storage temperature | -20 °C to +70 °C (non-condensation) |
| Relative humidity | 5 %RH to 95 %RH, non-condensation |
| Rated operational voltage | 12/24 VDC (±10 %) |
| Rated operational current | ≤120 mA (excluding motor drive) |
| MTBF | ≥10,000 hours |
| Annual repair rate | <1 % |
| Water-proof & dust-proof rating | IP20 |
| Size | 236 mm (length) × 156 mm (width) × 37.5 mm (height) |
| Weight | <1 kg |
| Display | 3.5 inch IPS color screen with multi buttons |
| Calibration capacitance range | 0.1 mm to 10 mm |
It is a fiber focus tracking controller that uses capacitive sensing to track and adjust the distance between the laser cutting head and the processing parts in real time.
It takes a DC input within the range of 12 V/24 V (±10%).
It supports one-button automatic calibration, which calibrates capacitance within the range of 0.1 mm to 10 mm.
The FTC unit operates from -10 °C to +55 °C, and storage is -20 °C to +70 °C with non-condensation.