This manual covers the installation, operation, maintenance, disassembly, inspection, and troubleshooting for the ASAHI AV H-V016-E-12 Gauge Valve.
This document is the Installation, Operation and Maintenance Manual for the ASAHI AV H-V016-E-12 Gauge Valve. It provides essential safety warnings, warranty information, and general operating instructions for users and technicians. The manual details the specific procedures for installing the valve on piping systems, including flange alignment and torque specifications, as well as operating the hand wheel to control fluid flow. This manual is written in Japanese.
| Nominal size | 20mm (3/4"), 25mm (1") |
|---|---|
| Gauge pipe Outside diameter (20mm) | 18mm (0.709 inch) |
| Gauge pipe Outside diameter (25mm) | 26mm (1.024 inch) |
| Flange Axial misalignment | 1.0mm (0.04 inch) |
| Flange Parallelism | 0.5mm (0.02 inch) |
The warranty extends for one and a half years after the product is shipped from the factory or one year after installation, whichever comes first.
Turn the hand wheel counter-clockwise to open and clockwise to close.
Required tools include a torque wrench, spanner wrench, monkey wrench, Phillips head screwdriver, protective gloves, and safety goggles.