Application instructions for the ArmorPoxy ArmorPower Epoxy Coating Kit, covering surface prep, mixing, application, clear coat, cleanup, and maintenance.
The ArmorPower Epoxy Coating Kit from ArmorPoxy is supplied with application instructions for floor coating work. The document lists kit contents and an installation chart, then explains required conditions, surface preparation, and application steps.
It covers removing foreign substances, pressure washing and etching, alternate floor grinding, taping the perimeter, floor repairs, mixing A and B epoxy, solid-color or decorative fleck application, clear coat, cleanup, return to service, maintenance, and a FAQ.
| Relative humidity | 80% or less |
|---|---|
| Minimum material temperature for installation | Above 60 °F |
| Maximum moisture level | 3.5 lbs/1000 sq ft/24 hours |
| Thinning | Up to 1/2 cup (4 oz) xylene per gallon of mixed materials |
| Suitable substrate | Bare concrete only |
ArmorPower Epoxy Coating Kits should be applied between 50-90 °F and when relative humidity is 80% or less.
Yes. ArmorPoxy may be thinned by adding up to 1/2 cup (4 oz) of xylene (xylol) per gallon of mixed materials.
Moisture levels over 3.5 lbs/1000 sq ft/24 hours are excessive and may need additional moisture treatment; contact ArmorPoxy for assistance.
It is intended to be applied to bare concrete only.