User's guide for the Applied Robotics QuickConnect MXC 5-20-75-160 tool change system, covering installation, operation, maintenance, and troubleshooting.
This manual provides instructions for the QuickConnect MXC 5 – 20 – 75 - 160 system, a tool change system for robotic manipulators. It details the system components, including the Master Assembly and Tooling Assembly, and explains the mechanical linkage used to connect and release tooling adaptors via air pressure.
The system requires a pressure to the tool changer of at least 4.9 bar (72 PSIG) for proper operation.
A single solenoid spring-return 4-way pneumatic valve is recommended for connecting air to the couple and uncouple ports.
The Master Adaptor Unit includes eight (8) M6 X 50 mm socket head cap screws for attaching the body to the plate.