The Anton/Bauer DIONIC 90 Owner's Manual explains features, charging, safety, specifications, warranty and transport rules for the lithium‑ion battery.
This manual provides an overview of the DIONIC 90 lithium‑ion digital battery, its microprocessor fuel computer, RealTime LCD display, Gold Mount interface and impact‑resistant case. It also details compatible Anton/Bauer InterActive 2000 or T Series chargers and the battery’s safety precautions.
The document includes charging procedures, nominal charge times, operating guidelines, service indicators, detailed specifications, warranty terms and transportation notices for safe handling and air shipment of the battery pack.
| Output Voltage | 14.4 V nominal, 12.4 ~ 16.8 V operating |
|---|---|
| Capacity | 90 Wh (6.3 Ah) |
| Internal Fuse | 8 A |
| Maximum Discharge Rate | 90 W |
| Typical Run‑time @ 20 W | 4.5 h |
| Weight | 1.7 lb |
| Dimensions | 5 ¼" × 3 ½" × 2 ⅛" |
| Charge Temperature Range | 0 °C – 40 °C |
| Discharge Temperature Range | -20 °C – 60 °C |
| Storage Temperature Range | -20 °C – 50 °C |
Only Anton/Bauer InterActive 2000 or T Series chargers listed in the manual may be used to charge the DIONIC 90 battery.