Anglia K52(H) PCB Mounting Relays Datasheet

Datasheet for the Anglia OKO type K52(H) sub-miniature DPCO PCB mounting relays with 150mW coil, silver alloy contacts rated up to 2A and IP67 sealing.


Anglia K52(H) PCB Mounting Relays Datasheet - cover page
Brand
Anglia
Category
electric relay
Document type
Datasheet
Language
English
Pages
1
File format
PDF
File size
86 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
28DBE0EEEC06B9323B9F86BF0C7BC524

About this manual

This single-page datasheet covers the OKO type K52(H) sub-miniature double pole changeover (DPCO) PCB mounting relays supplied by Anglia. The K52(H) high-sensitivity version features a 150mW low power consumption coil, while the standard K52 version uses a 450mW coil. Both use silver alloy, bifurcated contacts rated up to 2A, with DIL terminal pins on a 0.1 in grid and a fully sealed "watertight" construction. The relays are supplied in tubes.

The sheet lists the full specification, including contact ratings, coil power consumption and operating voltage range, operating and release times, life expectancy figures, and an operating temperature range of -30°C to +70°C. It also gives an ordering table with coil voltage/resistance options from 5Vdc to 48Vdc and their order codes, plus dimension drawings and a footprint schematic (pin view). Suggested applications include telecommunications, security and data processing.

What's inside

  • PCB Mounting Relays
  • OKO type K52(H) features
  • Specification
  • Contacts
  • Coil
  • Speed
  • Life expectancy
  • Operating temperature range
  • Order codes
  • Dimensions and footprint schematic

Specifications

Contact configurationDPCO, silver alloy, bifurcated
Contact rating (DC)2A, 24V, 60W
Contact rating (AC)1A, 120V, 60VA
Coil power consumption (K52(H))150mW (48V = 360mW)
Coil power consumption (K52)450mW
Operating voltage range75-150%
Operating time6ms
Release time4ms
Mechanical life expectancy20 x 10^6 operations min.
Electrical life expectancy1 x 10^6 operations min. @20mV/1kHz/1mA
Cable load life expectancy1 x 10^5 operations min. @2A, 24Vdc
Operating temperature range-30°C to +70°C
SealingFully sealed to DIN40050 (IP67)
CreepageVDE 0110 group A O
Coil voltage options (K52(H))5Vdc/167Ω, 9Vdc/540Ω, 12Vdc/960Ω, 24Vdc/3840Ω, 48Vdc/6400Ω
Coil voltage options (K52)5Vdc/56Ω, 9Vdc/180Ω, 12Vdc/320Ω, 24Vdc/1280Ω, 48Vdc/5100Ω
Terminal pinsDIL pins on a 0.1 in grid, hole dia. 0.8

Frequently asked questions

What coil voltage options are available for the K52(H) relay?

The K52(H) is available with 5Vdc/167Ω, 9Vdc/540Ω, 12Vdc/960Ω, 24Vdc/3840Ω and 48Vdc/6400Ω coils, with order codes 47W/5H, 47W/9H, 47W/6H, 47W/7H and 47W/8H.

What is the operating temperature range of the K52(H) relay?

The operating temperature range is -30°C to +70°C.

How much power does the K52(H) coil consume?

The high sensitivity K52(H) coil consumes 150mW (360mW at 48V), while the standard K52 coil consumes 450mW.

What are the contacts of the K52(H) rated for?

The DPCO silver alloy, bifurcated contacts are rated 2A, 24V, 60W DC and 1A, 120V, 60VA AC.

Download PDF (86 KB)

More Anglia Manuals


View all Anglia manuals →