AMP Solderless Termination Training Manual

A training guide for achieving quality solderless crimped terminals and splices using AMP PIDG and SOLISTRAND products.


AMP Solderless Termination Training Manual - cover page
Brand
AMP
Category
Other Electronics
Document type
User Manual
Language
English
Pages
32
File format
PDF
File size
5.5 MB
Published
23 October, 2026
Updated
23 October, 2026
MD5 checksum
E2932A2BD495DF4FF8BD2EE2928BA83D

About this manual

This guide provides instructions on achieving a perfectly crimped terminal or splice every time. It covers basic crimp techniques, the components of a good connection, and the advantages of using matched cable, terminal, and tooling from the AMP product range.

The document details specific terminal types such as PIDG (Pre-Insulated Diamond Grip) and SOLISTRAND, explaining their features like insulation support and colour coding. It also covers wire preparation, proper strip length, insulation crimp adjustment, dot coding, and methods for inspecting crimps using hand tools.

What's inside

  • Introduction
  • Basic Crimp Techniques
  • PIDG Terminals and Splices
  • Insulation Restricting PIDG Terminal
  • SOLISTRAND Terminals
  • Wire Barrel Functions
  • Wire Insulation Variations
  • Wire Preparation
  • Crimp Inspection
  • Tooling Information

Specifications

Terminal Body MaterialHigh grade copper, tin plated
Insulation Sleeve FeatureColour code matched to tool handle colours
Insulation Restricting Portion FunctionPrevents thin wire insulation from entering wire barrel
Wire Barrel FunctionProvides electrical and mechanical connection to wire conductor
Insulation Barrel FunctionProvides strain relief for wire insulation

Frequently asked questions

What are the components of a good connection?

The components include correct tooling for the terminal and wire, correct terminals for the application, properly prepared wire, and a properly trained operator.

What is the purpose of the insulation restricting portion on a PIDG terminal?

It provides a lead-in entry for the wire and prevents thin wire insulation from entering the wire barrel.

How should a wire barrel crimp differ from an insulation barrel crimp?

The insulation barrel requires a more relaxed crimp than the wire barrel crimp.