This manual covers the installation, operation, and maintenance of the Amiad Water Systems TEQUATIC PLUS F-150 Filter C-series Skid, including safety…
This document serves as the comprehensive installation, operation, and maintenance manual for the Amiad Water Systems TEQUATIC™ PLUS F-150 Filter, C-series Skid. It provides essential safety information, detailed system specifications, and an overview of the control system components.
The guide details the complete lifecycle of the equipment, covering site preparation, unpacking, and plumbing procedures. It also includes instructions for operating the control system, performing startup and shutdown sequences, and conducting maintenance tasks such as replacing filters and brushes.
| Max Inlet Pressure | 80 psi (5.5 bar) |
|---|---|
| Process Water Temperature | 45 - 140˚F (7-60˚C) |
| Ambient Temperature Range | 32 - 100˚F (0 - 37.8 ˚C) |
| Maximum Altitude | 6500 Ft (2000m) |
| Electrical Rating | 380-480V, 50/60Hz, 3-phase, 25A |
| Recirculation Pump | 10HP, VFD controlled |
| Dimensions (Length) | 92 in (234 cm) |
| Dimensions (Width) | 50 in (127 cm) |
| Dimensions (Height) | 85 5/8 in (217 cm) |
| Weight (Dry) | 2380 lb (1080 kg) |
| Weight (Wet) | 3050 lb (1385 kg) |
| Max. Particle Size | 0.07 in (2mm) |
The maximum inlet pressure is 80 psi (5.5 bar).
The process water temperature range is 45 - 140˚F (7-60˚C).
The skid measures 92 inches in length, 50 inches in width, and 85 5/8 inches in height.
The dry weight of the skid is 2380 lb (1080 kg).