About this manual

The SC-200 Signal Conditioner is a DIN-rail mounting, 24 Volt DC-operated module designed for AC LVDTs, RVDTs, LVRTs, and inductive half-bridges. It features a digital signal processor (DSP) and front-panel push buttons and LEDs for calibration and status indication.

This setup and operating instructions manual covers wiring configurations, a quick start guide, functional description, calibration procedures, failure diagnostics, troubleshooting, specifications, and appendices on error codes, cybersecurity features, and DIP switch settings.

What's inside

  • Identification of Front Panel LEDs and Switch Functions
  • Identification of DIP Switches and I/O connections
  • LVDT Wiring Configurations
  • Quick Start Guide
  • Functional Description of the SC-200
  • Calibration Procedure
  • Failure Diagnostics
  • Troubleshooting LVDT Connections
  • Specifications and Module Dimensions
  • Appendix A: Error Codes and Fault Matrix

Specifications

Excitation Frequency2.5, 5, 7.5, or 10 kHz
Analog Output Ranges0-5 V, 1-5 V, 0.5-4.5 V, 0-10 V, -10 to +10 V, 0.5-9.5 V, 0-20 mA, 4-20 mA
Power Input Voltage15 to 30 V DC
Failure Warning OutputOpen Collector Switch, 50 mA max.
Null Indicator OutputDifferential DC Output (floating)
RS-485 PortData Line (D+) and (D-)

Frequently asked questions

What types of sensors can the SC-200 Signal Conditioner be used with?

It is designed for AC LVDTs, RVDTs, LVRTs, and inductive half-bridges.

How is the excitation frequency selected on the SC-200?

The excitation frequency can be set to 2.5, 5, 7.5, or 10 kHz using DIP switches.

What analog output ranges are available on the SC-200?

The DS1 DIP switch can be configured to provide 0-5 V, 1-5 V, 0.5-4.5 V, 0-10 V, -10 to +10 V, 0.5-9.5 V, 0-20 mA, or 4-20 mA.

What is the power input voltage range for the SC-200?

It requires 15 to 30 V DC.

Download PDF (1.1 MB)