User instructions for Air Liquide 0459 Surgical Medical Argon, covering safety, usage, storage, and technical specifications for argon plasma coagulation.
This document provides usage instructions for Air Liquide 0459 Surgical Medical Argon, a Class IIa medical device used with argon plasma coagulation units. It details safety precautions, such as the risk of asphyxiation in confined spaces, and emphasizes that the gas is not sterile and must be used with compatible application materials. The manual outlines proper handling procedures for medical professionals, including connection methods and valve operation. This manual is written in Spanish.
| Product Class | Class IIa |
|---|---|
| Bottle Capacity | 1 m3 |
| Service Pressure | 200 bar |
| Valve Type | Residual pressure valve |
| Connection Standard | ISO 5145 n.º 4 |
| Bottle Material | Aluminum |
| Residual Pressure Range | 1.5 to 3.5 bar |
No, surgical medical argon is not sterile; it is recommended to use a 0.22 μ bacteriological filter.
Only trained healthcare professionals (surgeons, operating room nurses, biomedical technicians) authorized by the plasma knife distributor.
It can act as an asphyxiant by displacing air, making the atmosphere dangerous with less than 18% oxygen.