Aipu FK1-XXXXXE3 Series DC/DC Module Power Supply Datasheet

Aipu FK1-XXXXXE3 series 1 W DC/DC module power supply datasheet with input/output specs, pinout, package and application circuits.


Aipu FK1-XXXXXE3 Series DC/DC Module Power Supply Datasheet - cover page
Brand
Aipu
Category
DC/DC Converter
Document type
Datasheet
Language
Chinese
Pages
6
File format
PDF
File size
510 KB
Published
15 November, 2026
Updated
15 November, 2026
MD5 checksum
92A40F339B661392216965D35EAB8E9E

About this manual

This document is the datasheet for the Aipu FK1-XXXXXE3 series DC/DC module power supply, a 1 W converter with wide 2:1 input voltage ranges and single or dual outputs. It lists typical features, application fields, model selection, input and output characteristics, general characteristics, package dimensions, pin definitions, ripple and noise test notes, and design reference circuits.

The series includes single-output (S) and dual-output (D) variants with input ranges of 4.5-9, 9-18, 18-36 and 36-75 VDC. Key stated ratings include up to 82% efficiency, 3000 VDC isolation, -40 to +85 C operating temperature, 250 kHz typical switching frequency, and a 22 x 9.5 x 12 mm package. This manual is written in Chinese.

What's inside

  • Typical Features
  • Application Fields
  • Product Selection List
  • Input Characteristics
  • Output Characteristics
  • General Characteristics
  • Package Dimensions
  • Pin Definition
  • Ripple & Noise Test
  • Design Reference Applications

Specifications

Output power1 W
EfficiencyUp to 82%
Isolation voltage3000 VDC
Operating temperature-40 to +85 C
Storage temperature-55 to +125 C
Switching frequency250 kHz typical
Weight4.37 g typical
Package size22 x 9.5 x 12 mm
Ripple and noise100 mVp-p max (20 MHz bandwidth)

Frequently asked questions

What is the minimum load requirement?

The output minimum load should not be less than 10% of the rated load; if lower power is needed, connect a resistor equivalent to 10% of the rated load in parallel.

Can the module be used in parallel or hot-plugged?

The product cannot be used in parallel and does not support hot plugging.

What is the isolation voltage?

The isolation voltage between input and output is 3000 VDC.

How does the CTRL pin operate?

When floating or high impedance, the module outputs normally; a high level relative to input ground shuts it down.