Installation and technical specifications for the AIKVISION DS-PDP18-EG2 wired PIR detector.
This document is an installation guide for the AIKVISION DS-PDP18-EG2 wired PIR detector. It covers bracket and backplane installation methods, disassembly, the 18 m lens, sensitivity settings, resistor wiring, and power-up.
Technical specifications include detection range and speed, power supply, current consumption, temperature and humidity ranges, dimensions, and weight.
| Security grade | 2 |
|---|---|
| Environmental class | II |
| Detection range | FOV 90°, 84 zones, 7 levels |
| Mounting height | 1.8 to 2.4 m (typical 2.1 m) |
| Detection speed | 0.3 to 2 m/s |
| Sensitivity | High, Auto, Low |
| Auto sensitivity | Yes |
| Onboard EOL | Yes |
| Technology | Digital microprocessor based |
| Sealed optics | Yes |
| Creep zone protection | Yes |
| Tamper protection | Front |
| LED indicator | Blue (alarm) |
| Pet immunity | See PET Table above |
| Power supply | 9 to 16 VDC (standard: 12 VDC) |
| Current consumption | 12 mA quiescent, 7 mA alarm |
| Operating temperature | 10°C to 55°C (14°F to 131°F) |
| Storage temperature | -20°C to 60°C (-4°F to 140°F) |
| Operating humidity | 10% to 90% |
| Installation height | 1.8 to 2.4 m |
| Detector dimensions (H x W x D) | 86.8 mm x 65.4 mm x 45.5 mm |
| Weight | 68 g |
| Bracket | Optional wall and ceiling accessory |
| Alarm resistor values | 1K, 2K2, 4K7, 5K6, 6K8 |
| Tamper resistor values | 1K, 2K2, 4K7, 5K6 |
The operating temperature range is 10°C to 55°C (14°F to 131°F).
It requires 9 to 16 VDC, with 12 VDC as standard.
The detector measures 86.8 mm x 65.4 mm x 45.5 mm and weighs 68 g.
The indicator flashes rapidly, then goes out until movement is detected.