The Acces I/O PCI-IIRO-16 is a half-size PCI card that provides sixteen optically isolated inputs and sixteen electro-mechanical relay outputs for monitoring and controlling AC or DC signals in PCI-bus computers. The inputs accept 5 to 24V AC/DC with software-controlled filters and can generate interrupts on change of state. The relay outputs include ten Form C SPDT and six Form A SPST contacts rated at 1A at 24VDC and 0.5A at 125VAC.

The manual includes specifications, installation steps for DOS, Windows, and Linux, address selection, programming details, and connector pin assignments for the main bracket connector and optional breakout cable. It also covers warranty terms, safety warnings, and environmental operating ranges from 0°C to 50°C.

What's inside

  • Introduction
  • Specification
  • Block Diagram
  • Installation
  • Address Selection
  • Programming
  • Connector Pin Assignments
  • Breakout Cable Pin Assignments

Specifications

Isolated InputsSixteen non-polarized, optically isolated inputs
Input Voltage Range5 to 24V DC or AC rms (50 to 10000 Hz)
Input Isolation500V
Input Resistance470 ohms in series with two diodes and an LED
Input Response Time5 mSec with filter
InterruptsPCI-INTA on change of state
Relay OutputsSixteen outputs in two groups of eight (5 SPDT + 3 SPST per group)
Contact Rating1A max at 24VDC, 60VDC max, 0.5A at 125VAC max
Contact Resistance100 milliohm max
Contact Life5,000,000 operations minimum (mechanical)
Operate Time5 mSec max
Release Time5 mSec max
Output Isolation1000V
Power Required+5VDC 250mA min, 750mA max (all relays ON)
Operating Temperature0°C to +50°C
Storage Temperature-40°C to +85°C
Humidity0 to 90% non-condensing
WeightApprox. 8 oz
Size6.80" long (173 mm)

Frequently asked questions

What is the input voltage range for the PCI-IIRO-16 isolated inputs?

The isolated inputs accept 5 to 24V DC or AC rms at 50 to 10000 Hz.

What is the power requirement for the PCI-IIRO-16?

The card requires +5VDC at 250mA minimum and 750mA maximum when all relays are on.

What operating temperature range does the PCI-IIRO-16 support?

Operating temperature is 0°C to +50°C; storage temperature is -40°C to +85°C.