User guide for A.O. Smith water heater Part #701, covering troubleshooting, error codes, and circuit checks.
This manual provides step-by-step troubleshooting for common water heater issues such as slow hot water delivery, incorrect temperature, ignition failure, and communication errors. It includes detailed error code explanations (e.g., 031, 101, 111) and diagnostic procedures for power and water circuits. It also covers dipswitch settings, thermistor checks, and wiring diagrams for repair and maintenance.
The guide references specific components by part number (e.g., Part #409, #701) and includes appendices for voltage checks and thermistor resistance measurements. It is intended for technicians or users performing maintenance or repair on A.O. Smith water heaters with Part #701 PCBs. This manual is written in Chinese.
| Part Number | 701 |
|---|---|
| Minimum Water Flow | 0.5 GPM |
| Operating Voltage | 120 VAC |
The time depends on piping length and size; longer pipes take longer. Consider a recirculation system.
Check gas supply, Hi-limit switch, wire connections, burn marks on the board, and flame rod condition.
Check the voltage on the remote controller terminal on the PCB (normal: 11 to 25 VDC). Replace the remote controller if voltage is abnormal, or replace the PCB if voltage is normal.
Thermistor resistance values vary with temperature: 15.4 kΩ at 50°F, 5.9 kΩ at 95°F.