This document is the user manual for the GSK928TE/GSK928TC CNC system produced by Guangzhou CNC Equipment Co., Ltd. It provides information on the usage and precautions of the system.
About this manual
The manual provides safety guidelines, installation instructions, wiring diagrams, and setup procedures for the GSK928TE/GSK928TC CNC system. It emphasizes proper connection of the emergency‑stop button (normally‑closed contact) and correct grounding before powering the machine.
Detailed sections describe the system’s operation panel, manual and automatic operating modes, parameter configuration, tool‑offset settings, diagnostics, and programming basics. Appendices include wiring tables, connector pinouts, and contact information for Guangzhou Numerical Control. This manual is written in Chinese.
What's inside
- Overview
- Technical Specifications
- System Operation Panel
- System Operation
- Parameter Settings
- Tool Offset Settings
- Diagnostics
- Emergency Stop and Limit Alarms
- Programming Overview
Specifications
| Supported software version | V3.20 |
|---|
| RS232 communication baud rate | 9600 bps |
|---|
| RS232 signal level | Standard RS232 level |
|---|
| Maximum pulse output frequency (X5 drive) | 250 kHz |
|---|
| Pulse width (X5 drive) | 2 µs |
|---|
| Encoder power supply voltage | +5 V |
Frequently asked questions
What type of contact does the emergency‑stop button require?
The system uses a normally‑closed (NC) contact; connecting the button as normally‑open will cause an emergency‑stop alarm and prevent operation.
Which software version is this manual applicable to?
The manual applies to the GSK928TE/GSK928TC system running version V3.20 of the software.
What is the baud rate for the RS232 interface?
The RS232 interface operates at a baud rate of 9600 bps.