BC-2018 fingerprint access control integrated machine is a modern advanced access control system with three opening methods: fingerprint opening, ID plus fingerprint opening, and password plus ID opening. It has security measures such as door status monitoring, output alarm, security mode, and tamper prevention. Programmable functions include administrator password setting and modification, door status monitoring, and data output format. Programmable time includes opening time and alarm time. It has multiple interfaces including Wiegand data interface, alarm output interface, and relay output interface.
About this manual
The BC-2018 is an all‑in‑one fingerprint access controller that supports fingerprint, ID card, and password entry. It features a DSP processor, flash storage, and can manage up to 800 users with two fingerprints each, plus customizable output data.
The manual covers product overview, interface parameters, installation and wiring steps, power‑on procedure, programming mode (admin password, user addition, password changes), technical specifications, and a packing list. This manual is written in Chinese.
What's inside
- Product Overview
- Features
- Interface Parameters
- Installation and Wiring
- Power On Procedure
- Programming Mode
- Technical Specifications
- Packing List
Specifications
| Working voltage | DC 12V ±10% |
|---|
| Working current | 170 mA |
|---|
| Relay contact load capacity | 5 A |
|---|
| Alarm output load capacity | 150 mA |
|---|
| Operating temperature | -20 °C to 60 °C |
|---|
| Relative humidity | 20 % to 90 % |
|---|
| User storage capacity | 800 users, 2 fingerprints each, 10‑digit ID, 4‑digit password, 10‑digit custom output |
|---|
| Fingerprint enrollment time | ≤4 s |
|---|
| Matching time | ≤3 s |
|---|
| Search time | ≤2 s |
|---|
| False acceptance rate | 0.001 % |
|---|
| Dimensions | 165 mm × 90 mm × 32 mm |
|---|
| Weight | 250 g |
Frequently asked questions
How many users can the BC-2018 support?
It can manage up to 800 users, each with two fingerprints, a 3‑digit ID, a 4‑digit password, and a 10‑digit custom output.
What is the default administrator password?
The factory default administrator programming password is 9999.
What are the power requirements for the device?
It operates on a 12 V DC supply (±10%) and draws about 170 mA of current.