3onedata SW485UA Industrial RS-232/485 Interface Converter User Manual


3onedata SW485UA Industrial RS-232/485 Interface Converter User Manual - cover page
Brand
3One
Category
Converter
Document type
User Manual
Language
Chinese
Pages
1
File format
PDF
Published
21 October, 2011
Updated
29 September, 2023
MD5 checksum
8B6E504BD77E4BA4D87A57E2F9C71563

About this manual

This is the Chinese user manual (使用说明) for the 3onedata SW485UA, an interface converter that converts RS-232 signals to half-duplex RS-485 signals and back. The product is offered in optically isolated and non-isolated versions, uses a DB9 serial connector, and the manual states it is used in power systems, industrial automation control and IC card charging systems.

The manual lists the converter's functions and features, gives performance parameters and physical specifications, defines the pins of the RS-232 (DB9 female) end and the RS-485 (4-position terminal) end, and explains how to set the Isolated mode switch to NO (non-isolated, port-powered) or YES (isolated, external +5V required), with wiring diagrams for unit-to-unit and device connections. This manual is written in Chinese.

What's inside

  • 概述 (Overview)
  • 功能及特点 (Functions and Features)
  • 性能参数 (Performance Parameters)
  • 外观指标 (Appearance Specifications)
  • 引脚定义 (Pin Definitions)
  • 使用说明 (Operating Instructions)
  • 连线示意 (Wiring Diagram)

Specifications

Interface standardCompatible with EIA/TIA RS-232C and RS-485
Transmission rate0 to 115.2 Kbps
Transmission distance1.2 km at 9600 bps (RS-485 side); 5 m (RS-232 side)
Operating environment-40 °C to 80 °C, relative humidity 5% to 95%
Dimensions82 x 34 x 16.5 mm
Isolation2500V optical isolation in isolated mode (+5V supply)
Protection600W surge protection, 15KV electrostatic protection
Power consumption (active)Static under 30 mA, average dynamic under 100 mA

Frequently asked questions

How do I set the converter to non-isolated mode?

Set the mode switch marked Isolated to the NO side. In this mode the external power input is inactive and all power is taken from the serial port.

Does isolated mode need an external power supply?

Yes. When the Isolated switch is on the YES side, an external +5V power supply is required for normal operation.

What transmission rate and distance does the SW485UA support?

The manual states a transmission rate of 0 to 115.2 Kbps and a distance of 1.2 km at 9600 bps on the RS-485 side, 5 m on the RS-232 side.

How are the RS-485 terminal pins defined?

The 4-position terminal carries 485-, 485+, +5V power input and GND.