This manual describes the correct installation and configuration of PJP-EC200.
This manual contains safety precautions and detailed installation steps for the Yamaha PJP-EC200 conference system, including proper power connection, positioning, and handling of accessories. It also explains how to configure DIP switches, phantom power, and network settings.
The document lists the unit’s technical specifications such as dimensions, power requirements, audio performance, and interface options, and provides guidance for connecting microphones, speakers, and a PA system.
| Dimensions (W x H x D) | 270 mm x 42.6 mm x 180 mm (10-5/8" x 1-3/4" x 7-1/8") |
|---|---|
| Weight | 850 g (1.9 lbs) |
| Power supply | AC 100 to 240 V 50/60 Hz |
| Power consumption | 6 W maximum |
| Radio interference standard | VCCI Class A, KN22, KN24 |
| Operating temperature | 0 to 40 °C (32 to 104 °F) |
| Ambient humidity | 15 to 80 % (no condensation) |
| Audio range | 100 to 20,000 Hz |
| Maximum echo cancelling time | 400 ms |
| Maximum echo cancelling quantity | 60 dB |
| Maximum noise reduction | 17 dB |
| Interface | LINE OUTPUT (L/R) stereo RCA, CONFERENCE (IN/OUT) stereo mini jacks, MIC/LINE INPUT XLR/PHONE combo (2‑ch, 48‑V phantom supported) |
Use the dedicated AC adapter model PJP-PS02 that is supplied with the unit.
The unit consumes up to 6 W maximum.
Press and hold INITIALIZE while turning the unit on to reset all settings; pressing INITIALIZE while the unit is on resets only the network settings.