This manual describes the DAS software, a quantitative pharmacology tool used for bioequivalence, clinical pharmacology, and pharmacokinetic analysis. It explains the three main windows—entry, setting, and result—and guides users through data entry, parameter calculation, and result interpretation.

The document also covers experimental design rules, weighting methods, default equivalence criteria, and troubleshooting tips. It includes detailed sections on pharmacokinetic parameters, statistical matrix methods, and extensions such as tissue concentration modeling. This manual is written in Chinese.

What's inside

  • General Information
  • Important Tips
  • Data Processing
  • Bioequivalence Analysis
  • Experimental Design
  • Weighted Standard Curve
  • Pharmacokinetic Parameters
  • Error Analysis
  • Clinical Pharmacology

Specifications

Software version (upgrade path)1.0 → 2.0
Update date9/18/2007
User interface windowsEntry, Setting, Result
Default equivalence criteria (AUC)80%‑125%
Default equivalence criteria (Cmax)70%‑143%
Default equivalence criteria (Tmax for PBE)70%‑130%
Supported time unitsmin, h, d

Frequently asked questions

How do I enter data into the DAS software?

Open the entry window, select a function, click the [实例] button to load example data, then press [运行] to process the data.

What are the default equivalence limits for AUC and Cmax?

The software uses 80%‑125% for AUC and 70%‑143% for Cmax as the default equivalence standards.

How should low concentration data be handled?

If concentrations are very low, avoid log transformation and convert units (e.g., mg/L to µg/L) to increase the values before analysis.

What windows are available in the DAS software interface?

The program provides three windows: an entry window for data input, a setting window for parameters, and a result window for output.