This book introduces the troubleshooting guide for IBM System Storage SAN Volume Controller.
This guide applies to IBM System Storage SAN Volume Controller Version 8, Release 1, Modification 3, and to later releases and modifications unless a new edition states otherwise. It begins with an overview of the system, configuration nodes, management IP failover, and SAN fabric, then describes hardware components and parts for the 2145-SV1 and 2145-DH8 nodes and the 2145-92F, 2145-12F, and 2145-24F expansion enclosures.
Later chapters cover the management GUI, service assistant, command-line interface, service CLI, USB flash drive interface, and technician port. The guide also addresses critical product data, problem diagnosis, error codes and event logs, disaster recovery, recovery procedures, system configuration backup and restore, media errors, maintenance analysis procedures, and iSCSI performance analysis and tuning. This manual is written in Japanese.
| Supported node model | 2145-SV1 |
|---|---|
| Supported node model | 2145-DH8 |
| Expansion enclosure model | 2145-92F |
| Expansion enclosure model | 2145-12F |
| Expansion enclosure model | 2145-24F |
| Ethernet adapter | 10 Gbps |
| Ethernet adapter | 25 Gbps |
The SAN Volume Controller 2145-SV1 node.
The procedure applies to nodes reporting error code 550 or error code 578.
MAP5350 describes powering off a node.
Node attributes can be displayed with the CLI.