This document describes the information about IBM TotalStorage Enterprise Storage Server 00 attached to SIEMENS BS20, including system requirements, supported BS2000 servers, ESS models, ESS microcode level, ESS Advanced Copy Services, ordering ESS attached to BS2000, configuration, supported disk types and capacity planning, CV volumes, configuration example: 2105-F20 with 6 LSS, configuration example: IOCP (UGEN) 6 LCUs/4 CHPID/256 dev, configuration example: IOCP (UGEN) 6 LCUs/8 CHPID/128 dev, recommended disk type definition for UGEN, supported controller types, and important links.
This attachment guide describes how IBM TotalStorage Enterprise Storage Server (ESS) 2105 models are attached to SIEMENS BS2000/OSD servers over ESCON. It lists the requirements: BS2000/OSD Version 4.0, supported S1xx and SR2000 server models with ESCON channels, ESS models with an ESCON host bus adapter and ESS microcode level 1.4.1.5 or higher. It also notes that PPRC and FLASHCOPY are supported using ESS Specialist, and that an RPQ must be generated before an ESS is ordered.
The configuration section maps Fujitsu-Siemens disk types (D3490-10, -20, -30, -40) to IBM 3390-1, -2, -3 and -9 types and gives cylinder counts and capacities, CV volume ranges, and example 2105-F20 layouts with 6 LSS. Further examples show IOCP (UGEN) definitions for 6 LCUs with 4 or 8 CHPIDs, the recommended dynamic disk type AA for UGEN, and supported controller (LCU) settings for 3990 emulation with up to 16 LCUs of 256 addresses each. The document closes with links to IBM storage pages and the Fujitsu-Siemens BS2000 server list.
| Operating system requirement | BS2000/OSD Version 4.0 |
|---|---|
| Supported connections | ESCON only |
| Required ESS microcode level | 1.4.1.5 or higher |
| Maximum LCUs | Up to 16 LCUs, each 256 addresses |
| Maximum logical volumes | 4096 |
| 3390-9 equivalent disk (D3490-40) | 10017 cylinders; 8,514 / 7,385 / 6,462 / 5,847 GB depending on format |
| CV volume range reported as 3390-3 | 1 - 3339 cylinders (D3490-30) |
| LCU emulation | 3990 (Siemens BS2000 compatible) |
BS2000/OSD Version 4.0 is a prerequisite for running BS2000 attached to ESS.
The ESS must run with microcode level 1.4.1.5 or higher.
Only ESCON connections are supported.
Up to 16 LCUs, each with a maximum of 256 addresses.