The IBM Cloud Object Storage System™ Slicestor® 2584 Appliance Manual provides information about the IBM Cloud Object Storage System™ Slicestor® 2584 appliance.
This is the IBM Cloud Object Storage System Slicestor 2584 Appliance Manual, edition Version 3.13.4, applying to machine types 3409-S03, 3401-S03 and 3403-S03. It begins with safety and environmental notices, including the declared noise emissions and support information, and then describes the enclosure chassis, its core components, the 2200 W and 2800 W power supply units, the cooling modules and the AP-TL-1 and AP-LS-1 compute modules.
The manual then covers installation and preparation, power cord connection and grounding checks, daily operation such as power on and power down, the ops panel LEDs and the anti-tamper drawer locks, and troubleshooting with LED tables, thermal sensors and hardware faults. A module replacement chapter gives procedures for replacing a disk drive in carrier (DDIC), a cooling module, a power supply unit and a compute module, and for battery removal. Appendixes list technical specifications (dimensions, components, thermal, temperature and humidity, PSU and compute module data, supported drives, shock and vibration), standards and regulations, and POST codes.
| Height (enclosure, overall) | 8.75 in (222.3 mm) |
|---|---|
| Width across mounting flange | 19 in (482.6 mm) |
| Depth | 36 in (915 mm) |
| Operating temperature range | 41°F (5°C) to 95°F (35°C) |
| Operating relative humidity | 20%rh to 80%rh non-condensing |
| Airflow with all fans running | 4.24 cubic feet (120 liters) per second maximum |
| Cooling module fans | Two stacked fans, 80 mm x 80 mm x 38 mm |
| PSU output power (2200 W PSU) | 2214 W maximum continuous output power at high line voltage |
| PSU input voltage range | 200 - 240 VAC, 50 - 60 Hz |
| Components (fully populated) | 2 drawers, 84 DDICs, 1 compute module, 2 PSUs, 5 cooling modules |
Operating temperature is 41°F (5°C) to 95°F (35°C) with relative humidity of 20%rh to 80%rh non-condensing.
There are five cooling modules, each containing two stacked 80 mm x 80 mm x 38 mm fans.
Both the 2200 W and 2800 W PSUs accept 200 - 240 VAC at 50 - 60 Hz.
A fully populated enclosure holds 84 disk drives in carriers (DDICs) across two drawers.