The IBM TotalStorage SAN Switch 2109 Model M12 is a high-performance, scalable storage area network (SAN) switch designed to meet the demands of today's demanding enterprise storage environments. It provides a flexible platform that can be scaled to meet growing storage needs while delivering high levels of performance and reliability.
This is the IBM TotalStorage SAN Switch 2109 Model M12 Installation and Service Guide, publication GC26-7633-00, first edition dated May 2004. It covers the Model M12 switch from initial power-on and configuration through day-to-day operation, modem installation, mounting in or removal from a cabinet, and servicing field replaceable units such as 16-port cards, CP cards, power supplies, blower assemblies, the cable management tray and the WWN card. It also documents LED and POST interpretation, safety and environmental notices, and the procedure for upgrading an M12 to an M14.
Appendix A gives the product specifications for the M12 only: chassis dimensions and component weights, 16-port card, CP card and fibre-channel port specifications, facility, power, environmental, general, regulatory and POST/boot specifications. Further appendixes provide the Model M12 parts list and blank planning worksheets for ports and zones, followed by notices and a glossary.
| Height | 14U (24.11 in.) |
|---|---|
| Depth | 70.9 cm (27.9 in.); 72.9 cm (28.7 in.) with door |
| Width | 43.7 cm (17.2 in.) |
| Rack mounting | 48.26 cm (19 in.) rack |
| 16-port cards | Up to eight cards per chassis, 16 optical ports per card, SFP compatible |
| Power supplies | Four, with built-in fans |
| Blower assemblies | Three, for forced-air cooling of the 16-port cards and CP cards |
| Blower high speed threshold | Inlet air temperature above 33° C (91° F) |
| CP card Ethernet connector | IEEE compliant RJ-45 for 10 Mbps or 100 Mbps Ethernet |
| CP card real-time clock | 10-year battery and 56 bytes of NVRAM |
The chassis supports configurations of up to eight 16-port cards, each with 16 optical ports compatible with SFPs.
The blower speed is governed by inlet air temperature, and the blowers go into high speed when the inlet air temperature exceeds 33° C (91° F).
It has four power supplies with built-in fans that plug into internal blind-mate connectors.
Each CP card has one modem serial port and one terminal serial port on DB-9 connectors, plus an RJ-45 Ethernet connector.