This manual explains how to assemble a cable to DIS receptacle connector.
This manual provides detailed instructions for assembling cables to the DIS30-R42P receptacle connector. It covers cutting and stripping cables, crimping contacts, inserting contacts into the housing, and removing the insert. Each step includes specific measurements and warnings to prevent errors. The manual is issued by DDK Ltd. and includes part numbers for tools and components used in the process.
The document is written in Japanese with English translations for key terms and instructions. It is intended for technicians performing cable assembly and includes safety notes and tool specifications to ensure proper installation.
| Connector Name | DIS30-R42P |
|---|---|
| Manual No. | TC-655 |
| Cable Length After Cutting | 12mm + Standard of length |
| Cable Jacket Stripping Length | Dimension A |
Cut the cable to 12mm plus the standard length for the DIS30-R42P connector.
This manual explains how to assemble a cable to DIS receptacle connector.
Cut the cable to 12mm plus the standard cable length.
Use the contact removal tool 357J-51374T.