AMCTECH X-ray Thickness Gauge Instruction Manual

X-ray thickness gauge is a kind of online high-precision metal strip thickness detection instrument, which can quickly and accurately reflect the actual thickness or thickness deviation of the strip in the production process of metal strip, and will not release any rays after power failure. It is a safe thickness gauge with convenient use and reliable performance.


AMCTECH X-ray Thickness Gauge Instruction Manual - cover page
Brand
AMCTECH
Category
Other products
Document type
User Manual
Language
Chinese
Pages
21
File format
PDF
File size
2 MB
Published
29 November, 2023
Updated
29 November, 2023
MD5 checksum
399BC5850C5BC2855C6F141A506D29EA

About this manual

AMCTECH X-ray thickness gauge is an online high-precision instrument for measuring metal strip thickness during production. It uses X-ray attenuation through the material to determine thickness and can interface with an AGC system for thickness control.

The gauge consists of a C-frame with an X-ray tube and ionization chamber, plus an instrument box, control cabinet, cooling system and digital display. The manual covers installation, debugging, software operation, calibration, routine maintenance, fault diagnosis, transport and storage. This manual is written in Chinese.

What's inside

  • System overview
  • Measurement principle
  • Technical parameters
  • Hardware composition
  • Safety protection
  • Component structure and functions
  • Installation
  • Debugging
  • Software operation
  • Daily maintenance and fault diagnosis

Specifications

Gauge dimensions1930 x 200 x 611.5 mm (excluding drag chain)
X-ray tube voltage65.0 kV
X-ray tube current0.10 mA
Power6.50 W
C-frame opening723 x 150 mm
Dynamic measurement accuracy±0.001 mm
Measurement range0-3.0 mm
Measuring frame travel475 mm
Stroke cylinder working pressure16 MPa
ResolutionSensor 0.001 mm, digital display 0.0001 mm
Output signalDeviation +/-10 V, 232 communication/parallel BCD
Follow-up capability1000 m/min
Radiation dose at front of C-frameLess than 2.5 μSv/h

Frequently asked questions

What password is used to log in to the thickness gauge software?

The login password is "Amc2005".

What is the measurement range of the gauge?

The measurement range is 0-3.0 mm.

What is the dynamic measurement accuracy?

The dynamic measurement accuracy is ±0.001 mm.

Which radiation protection standard does the gauge meet?

It meets GB18871-2002, the basic standard for ionizing radiation protection and radiation source safety.