This document describes the features and specifications of the TORUS 3D tank cleaning head product.
This document is the Chinese-language user manual for the StoneAge TORUS TR-130 and TR-200 3D tank cleaning heads. It lists model specifications, safety warnings, operating instructions, accessory fitting, maintenance procedures and warranty terms.
The TR-130 is described for cleaning tanks, large containers, autoclaves, large pipes and reactors, with a maximum working pressure of 22,000 psi (1500 bar) and a flow range of 10 to 80 gpm. The manual explains selecting flow modules and nozzles, adjusting rotation speed with the speed control shaft, and replacing high-pressure seals. The TR-200 specifications include a pressure range of 8–15k psi (550–1035 bar) and a flow range of 50–220 gpm (190–830 l/min). This manual is written in Chinese.
| TR-130 pressure range | 2–22k psi (138–1500 bar) |
|---|---|
| TR-200 pressure range | 8–15k psi (550–1035 bar) |
| TR-130 flow range | 10–81 gpm (38–307 l/min) |
| TR-200 flow range | 50–220 gpm (190–830 l/min) |
| TR-200 rotation cycle | 10–88 minutes |
| TR-130 diameter | 5.12 in. (130 mm) |
| TR-200 diameter | 8.0 in. (200 mm) |
| TR-130 length | 17 in. (432 mm) |
| TR-200 length | 22.8 in. (579 mm) |
| TR-130 weight | 35 lbs (16 kg) |
| TR-200 weight | 100 lbs (45 kg) |
| Maximum water temperature | 160°F (70°C) |
The TR-130 pressure range is 2–22k psi (138–1500 bar).
The TR-200 flow range is 50–220 gpm (190–830 l/min).
Use compressed air to blow dry residual water from the nozzles, overflow holes and inlet connection.
The TR-200 weighs 100 lbs (45 kg).