The Froment SIGMA Dynamometers User Manual describes the features and specifications of the Sigma dynamometer.
This user manual covers Froment Sigma 50 and Sigma 60 dynamometers, which are purpose-built for testing agricultural engines by connecting to a vehicle's PTO output. The units are mains powered, air cooled, and trailer mounted for mobile operation, with a static mounted option for fixed installations.
It provides instructions for safe transportation, installation and setup, including PTO shaft connection and tractor positioning. The manual also explains how to use the hand-held controller, perform routine maintenance, and respond to warning and error messages.
| Maximum Power (Sigma 50) | 380kW (515 PS) @1000 rpm |
|---|---|
| Maximum Torque (Sigma 50) | 3170Nm @800 rpm |
| Kerb Mass (Sigma 50) | 1780kg |
| Cooling System | Side venting, mains powered forced air |
| Maximum shaft rotation speed | 1250 rpm |
The maximum power is 380kW (515 PS) at 1000 rpm.
They are air cooled and require no cooling water.
All guards, covers and protective screens must be in place and secured.
Yes, bare diesel engines can be tested by direct coupling if required.