AKIRA AC-CA50CG Air Conditioner Service Manual

The document describes the specifications, outline & dimensions, exploded view & part list, installation guide, circuit diagram and PCB function manual of the AC-CA50CG model air conditioner.


AKIRA AC-CA50CG Air Conditioner Service Manual - cover page
Brand
akira
Category
Air conditioner
Document type
Service Manual
Language
English
Pages
38
File format
PDF
File size
3.6 MB
Published
29 November, 2023
Updated
29 November, 2023
MD5 checksum
88D76546A131964291A5F768CA4C626E

About this manual

The AKIRA AC-CA50CG Air Conditioner Service Manual provides technical information for the unit, including specifications, outline and dimensions, exploded views and parts lists, an installation guide, circuit diagrams and PCB function notes. It is marked as version 1.0.

The specifications identify a 3-phase 380–400 V 50 Hz power supply, R407C refrigerant, and a scroll compressor. The manual also describes low-power protection, water pump and water-full protection, button operation and the auto-restart function.

What's inside

  • Specifications
  • Outline & Dimensions
  • Exploded View & Part List
  • Installation Guide
  • Circuit Diagram
  • PCB Function Manual
  • Protecting of low power
  • Protecting of water pump control and water full
  • Buttons
  • Auto-restart function

Specifications

Power supply3-phase 380–400 V, 50 Hz
Capacity12000
Rated input2600 W
Air flow1860
Dehumidifying volume7.0 L/h
RefrigerantR407C
Refrigerant charge3.8 kg
Compressor modelC-SBN373H8A
Fan motor modelFW68D
Fan motor speed840/640 rpm
Throttling methodCapillary
Defrosting methodAuto defrost
Noise<53 dB(A)
Main body dimensions840 x 840 x 320 mm
Panel dimensions950 x 950 x 60 mm
Outdoor unit dimensions950 x 1250 x 412 mm
Outdoor unit net weight112 kg

Frequently asked questions

What refrigerant does the AC-CA50CG use?

It uses R407C refrigerant.

How much refrigerant does the unit contain?

The refrigerant charge is 3.8 kg.

What is the defrosting method?

The unit uses auto defrost.

Does the AC-CA50CG restart automatically after a power break?

Yes. It can restart according to memorized mode, swing, set temperature and set speed, with a 3-minute compressor delay on the first restart.