Entrust nShield Solo and nShield Solo XC Hardware Security Module Installation Guide

The nShield® Solo and nShield® Solo XC Installation Guide describes how to install and configure the nShield® Solo and nShield® Solo XC Hardware Security Modules (HSMs).


Entrust nShield Solo and nShield Solo XC Hardware Security Module Installation Guide - cover page
Brand
Entrust
Category
Expansion card
Document type
Installation Guide
Language
English
Pages
49
File format
PDF
File size
3.3 MB
Published
29 November, 2023
Updated
29 November, 2023
MD5 checksum
60C3824D10A2A36C879B4887402C0CAF

About this manual

This 49-page guide describes installing the Entrust nShield Solo and nShield Solo XC hardware security modules in servers and appliances. It covers power and environmental requirements, handling, regulatory notices, back-panel controls and jumper switches, module and smart card reader installation, and fan or battery replacement.

What's inside

  • Introduction
  • Hardware security modules
  • Regulatory notices
  • Before installing the module
  • Installing the module
  • Installing the software
  • Checking the installation
  • Status indicators
  • Uninstalling existing software
  • Virtualization Remote Server

Specifications

Module typeHardware Security Module (HSM) for servers and appliances
Model numbers for nShield Solo PCIexC3xxxE-xxx, xC4xxxE-xxx
Model numbers for nShield Solo XC PCIexC30x5E-xxx, xC40x5E-xxx
Maximum powerSolo: 9.9 W; Solo XC: 24 W
Solo ambient operating temperature10°C to 35°C
Solo XC ambient operating temperature5°C to 55°C
CertificationNIST FIPS 140-2 Level 2 and 3

Frequently asked questions

What power supply capacity do nShield Solo and Solo XC need?

The Solo module has a maximum power of 9.9 W, and the Solo XC has a maximum power of 24 W. The computer power supply must be rated to supply the required power.

How can I check the nShield module temperature after installation?

You can use the supplied stattree utility to check the module's actual and maximum temperature during operation.

What happens if the nShield module exceeds its safe operating temperature?

The module stops operating and displays the SOS-T error message on the Status LED.